Model MS-1000 Operation Manual Manual: xxxxxx Issue:xx
RS-232 data commands for SBI protocol The RS232 can be set so a bidirectional connection can be established between the indicator and the host. To e
Other RS-232 Output Strings P4-1 = Output Displayed data @ print key : Format: <LF>< reading, minus, decimal point, weight unit><C
Scale calibration Calibration Configuration Settings – The scale is configured from the factory to match the specified settings for each unit, as de
1. On/OffZero+Tare 2. Tare 3. Tare 4. Enter in calibration weight from 25% to 100% full capacity 25%-100% kg/lb
Service Configuration Settings The scale is configured from the factory to match the specified settings for each unit, as defined by the product speci
Technical Specifications Scale Indicator Input signal range: 0mV ~ +30mV Sensitivity: >0.2uV/grad Internal Resolution: Approximatel
UK and EuropeBrecknellFoundry Lane Smethwick,West Midlands, B66 2LP.Tel: +44 (0) 845 246 6717Fax:
©Avery Weigh-Tronix, LLC. All rights reserved. The information contained herein is the property of Avery Weigh-Tronix and is supplied without liabili
Contents WARNINGS ...
Setting the Indicator Up for Use RS232Loadcell socketPower/Adapter Socket Power Supply Connecting the Indicator to the Platform -6V DC
Display and Keypad Function Keys AnnunicatorsTareTTare Zero0 Weight is zero On/OffZeroOn/Off/Zero kg lb Unit of measure (Flashing LED means t
Scale Operation Turning On and Zeroing the Scale On/OffZero ZERO0 Turning off the scale On/OffZero Selecting Unit of Measure
Hold function with automatic zero on next weigh. 1. HoldPrint Hold 2. 3. 4. Hold Hold function with man
1. 2. HoldPrint 3. Print USER CONFIGURATION SETTINGS Setup Controls Entering setup On/OffZero + Units
User Configuration Settings Parameter Setting Default settings in boldP1.xy Auto shutoff timer in minutes Set up time for the auto off function. (