User’s Manual61XX SeriesPPPPPortion Control Scalesortion Control Scalesortion Control Scalesortion Control Scalesortion Control ScalesModel 6103Model

Pagina 2 - 7/09/01 - PN 7424-16911

4. Remove the item from the scale and thedisplayed weight should return to “0.00” andthe scale is ready for the next item.Net Weighing (with a contain

Pagina 3 - Table of Contents

4. When the required weight measurement isachieved, press the ZERO key and the scalewill again display zero “0.00.”5. Continue the same sequence until

Pagina 4 - Specifications

The TEST key menu allows access to the followingfeatures: UNDO O, SENSOR (if equipped-SeeSENSOR feature in the CONF Menu Mode),TEST,DONE.When in nor

Pagina 5

Press the TEST key to return to normal operationwithout performing any of the above functions.The TEST key is also used to select an item orfeature wh

Pagina 6

The 61xx scale powers up in normal weighing modeready for weighing operations. You can access theMENU mode by pressing SW-1 accessed fromthe bottom of

Pagina 7 - Initial Setup

Figure 3Menu Structure12

Pagina 8

The Diagnostic (DIAG) Mode menu lets you testspecific areas of the unit’s function.The items in the Diagnostics menu are as follows:Display (DISP) – S

Pagina 9 - Operation

Press the ZERO key to scroll to the I/O test. “I/O” isdisplayed. With a loopback connector in place,press the TEST key to perform the I/O test. “PASS”

Pagina 10

From normal weighing mode press SW-1…“DIAG” is displayed.Press the ZERO key until…“CONF” is displayed.Press TEST key to access the Configuration m

Pagina 11 - Operator Controls

From “FILT” press the ZERO key twice…“SENSOR” is displayed (only on equipped models).From this routine you can adjust the sensitivity, viewthe current

Pagina 12

UNITED STATESThis equipment has been tested and found to comply with thelimits for a Class A digital device, pursuant to Part 15 of the FCCRules. Thes

Pagina 13

To access the Sensor On-Off menu, press the TESTkey. The current state “ON” (or “OFF”) of the photoeyewill be displayed. Pressing the ZERO key willtog

Pagina 14 - Menu Modes

1. From normal weighing mode press SW-1…“DIAG” is displayed. Press the ZERO keyuntil “CAL” is displayed..2. Press the TEST key to access the Calib

Pagina 15 - Menu Structure

6. Place chosen span calibration weight on thescale and wait for the scale to stabilize;then press the TEST key. The display will flashdashes and the

Pagina 16 - Diagnostics Mode

Press the TEST key to access the Units menu. Ifthe scale is currently in the gram unit of measure,the display will flash “CAN’T” and then return todis

Pagina 17 - Configuration Mode

*Note: All Jmp1 pins 1, 4, and 6 and all Jmp2pins 7 and 8 are connected internally inside thescale connector.**External Zero Control Line: The optiona

Pagina 18 - “48-e” “48-o” “48-n”

Err-4 Zero ErrorIf a zero error “Err-4” occurs, it is becausethe weight was not stable, or it was undercapacity (lower dashes), or over capacity(up

Pagina 19

3. DO NOT submerge the scale base or display inwater.4. DO NOT use acetone or other solvents to cleanthe scale.5. DO NOT expose to extreme temperature

Pagina 20 - Calibration Mode

Missing or extra segments on display1. Replace the display board.2. Replace the main board.Scale will not return to zero, or incorrect weight isdispla

Pagina 21

Scale is not transmitting data to the host device1. Check cable connection at both the rear of thescale and the host device.2. Check communication set

Pagina 22 - Units Mode

Display Brackets 6112/6115 Rear Flat 1067-16866 6112 Front/6103 Side Standard 1067-17061 6103 Front 6" Shelf 1067-17064 6112 Front/6103 Side Shel

Pagina 23 - Communication Mode

Table of ContentsDescription... 1Specifications ... 1Initial Se

Pagina 24 - Error Codes

16" Cable w/Top Exit 7516-xxxxx-366112/6115 Rear Flat Bracket9" Cable w/Top Exit 7516-xxxxx-396103 Side Shelf BracketRemote Zero Footswitch

Pagina 26 - Troubleshooting

1000 Armstrong DriveFairmont, MN 56031Telephone: 507-238-4461Facsimile: 507-238-4195E-mail: [email protected]: www.wt-nci.com

Pagina 27

Capacity andResolutionNOTE:NOTE:NOTE:NOTE:NOTE: The number afterthe dash indicates thescale rated capacity in kg.Agency ApprovalsAccuracyDimensionsPow

Pagina 28 - Spare Parts and Accessories

Input: 120 VAC +10%, -15% Standard 3-wirew/ground inputOptional: 230 VAC +10%, -15% UniversaladapterOutput: 15 VDC @ 0.3 Amps DC minimumUL and CE appr

Pagina 29

Initial zero value established on power up if within25% of full scale and the calibrated zero value.Center-zero indicated up to 1/2 division. Fullcapa

Pagina 30

1. Check carton for any obvious evidence ofdamage.2. Remove contents from the shipping carton.3. Inspect the unit for shipping damage. Immedi-ately re

Pagina 31

8. Verify that the power cable (round end) isplugged into the scale power input connector,then plug the line cord adapter into an appro-priate, proper

Pagina 32

On some models, the scale comes equipped withtwo magnetic strips to mount the display to anysuitable surface. Remove the backing from one ofthe magnet

Modelli collegati 6112 | 6103 |