Salter-brecknell 7821 Manuale Utente

Navigare online o scaricare Manuale Utente per Bilance Salter-brecknell 7821. Salter Brecknell 7821 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - User’s Manual

User’s ManualModel 7821Bench Scale

Pagina 2 - 11/19/02 PN 7424-15813E e1

Model 7821 Bench Scale User’s Manual10Diagnostics ModeScale lb/kgCapacity andCount-by ChoicesTable 3:Scale lb/kg Capacity and Count-by ChoicesCapacity

Pagina 3 - Table of Contents

Model 7821 Bench Scale User’s Manual11Follow these steps to access the tests in theDIAG menu.1. From normal weighing mode, move Switch 1to the MENU Mo

Pagina 4 - Specifications

Model 7821 Bench Scale User’s Manual127. Press the UNITS key to perform the ROMtest…PASS or FAIL is displayed. If the testfails, contact your local We

Pagina 5 - Operation

Model 7821 Bench Scale User’s Manual1316. Press the ZERO key. . .LOC-G is displayed. This stands for localgravity or current gravity setting.17. Press

Pagina 6 - Modes of Operation

Model 7821 Bench Scale User’s Manual14The Configuration (CONF) Mode menu allowsconfiguration of the scale to the specific applica-tion need. The items

Pagina 7

Model 7821 Bench Scale User’s Manual15114. Use the ZERO key to toggle between the twochoices. Press the UNITS key when thechoice you want is displayed

Pagina 8 - Menu Structure

Model 7821 Bench Scale User’s Manual16The Calibration (CAL) Mode menu allows scalecalibration. The items in the Calibration menu areas follows:Pounds/

Pagina 9 - Baud Rate and Parity Options

Model 7821 Bench Scale User’s Manual17If no span weight isapplied, calibration willbe aborted. “CALERROR ABORT” willbe displayed.4. Press the ZERO key

Pagina 10 - Diagnostics Mode

Model 7821 Bench Scale User’s Manual18Gravity ModeWarning: Using thisfeature in “sealed”applications may besubject to approval bythe appropriategovern

Pagina 11

Model 7821 Bench Scale User’s Manual19CommunicationError CodesAny system errors detected by the scale will bedisplayed as the letter E followed by a t

Pagina 12

Model 7821 Bench Scale User’s Manual2UNITED STATESThis equipment has been tested and found to comply with thelimits for a Class A digital device, purs

Pagina 13

Model 7821 Bench Scale User’s Manual20SerialCommunicationsProtocolNCICommunicationsProtocol DE-9 Female Scale DE-9 Male Host Pin Name Directio

Pagina 14 - Configuration Mode

Model 7821 Bench Scale User’s Manual21W<CR>Scale Response<LF>xxxx.xxuu<CR><LF>hh...<CR><ETX>ResultsReturns decimal

Pagina 15

Model 7821 Bench Scale User’s Manual22RECOMMENDED ACTIONPerform each step in sequence until the symp-tom is resolved. Once the symptom is resolved,dis

Pagina 16 - Calibration Mode

Model 7821 Bench Scale User’s Manual23Spare Parts ListDescription Part NumberKeyboard Panel 1163-15803Display PCB 7405-15465Loadcell (100kg) 7154-1633

Pagina 17

Model 7821 Bench Scale User’s Manual24Notes

Pagina 18 - Gravity Mode

Model 7821 Bench Scale User’s Manual25Notes

Pagina 19 - Error Codes

Model 7821 Bench Scale User’s Manual26

Pagina 20

Model 7821 Bench Scale User’s Manual27

Pagina 21

1000 Armstrong DriveFairmont, MN 56031Telephone: 507-238-4461Facsimile: 507-238-4195E-Mail: [email protected]

Pagina 22 - Troubleshooting

Model 7821 Bench Scale User’s Manual3Table of ContentsTable of Contents ... 3Specifications ...

Pagina 23 - Spare Parts List

Model 7821 Bench Scale User’s Manual4 Model #Capacity (lb) Capacity (kg) Divisions7821-70 150 x .05 lb 60 x .02 kg 3000d70 x .02 kg 3500d7821-75 7

Pagina 24

Model 7821 Bench Scale User’s Manual51. Remove contents of the shipping container.2. Inspect the scale for shipping damage.Immediately report any dama

Pagina 25

Model 7821 Bench Scale User’s Manual6Top view of 7821 scale with platter removed.Modes of OperationPerforming a NormalWeighmentAccessing the MenuIf ev

Pagina 26

Model 7821 Bench Scale User’s Manual7There are three modes available to you withSwitch 1 in the MENU Mode or OPEN position.They are as follows:Diagnos

Pagina 27

Model 7821 Bench Scale User’s Manual8Figure 2Menu Structure

Pagina 28

Model 7821 Bench Scale User’s Manual9The NCI 7821 bench scale allows calibration ofthe scale using less than full capacity weights.The following table

Commenti su questo manuale